Why do power lines use such high voltages?
A line of pylons carries electricity across Ireland at 110 000 volts or more, yet a plug socket gives only 230 volts. Why the difference?
Unit 5: Magnetism and Electromagnetic Induction
Images coming soon — الصور تُضاف قريبًا
This content follows the official curriculum and has not been reviewed yet. المحتوى كما في المنهاج الرسمي ولم يراجعه أحد بعد.
A line of pylons carries electricity across Ireland at 110 000 volts or more, yet a plug socket gives only 230 volts. Why the difference?
A line of pylons carries electricity across Ireland at 110 000 volts or more, yet a plug socket gives only 230 volts. Why the difference?
A generator produces an alternating emf V equals V₀ sin ωt. The peak voltage is V₀ and the rms value is V₀/√2, about 0.707V₀. The rms value is the steady DC voltage that gives the same heating effect. Irish mains is 230 V rms at 50 Hz. A meter normally shows rms values. Power in a resistor is P equals V_rms I_rms.
Irish mains is 230 V rms. Find the peak voltage.
A transformer changes the size of an alternating voltage using two coils on an iron core. The ratio equals the turns ratio V_s/V_p equals N_s/N_p. A step-up transformer has more turns on the secondary and a step-down transformer fewer. For an ideal transformer power in equals power out so V_pI_p equals V_sI_s. Transformers only work with alternating current because they need a changing flux.
A transformer steps 230 V down to 12 V and the primary has 1150 turns. Find the secondary turns.
Why is electricity transmitted at very high voltage?
50 kW is sent through cables of resistance 0.50 Ω at 200 V and then at 20 000 V. Compare the heat loss.
A transformer will not work with:
V_rms equals V₀/√2. Transformers work with AC, with V_s/V_p equals N_s/N_p. Transmitting at high voltage cuts the current and so the I²R loss.